Daikin Error Code List: What the Blinking Codes Mean

Quick answer A Daikin error code is a letter and number pair that tells you which part the AC is unhappy with. On most models you can try a safe restart, then call authorised service.

Appliance codeL5, U0, E9, C4
Impact
Medium impact
Typical fix time
Minutes to a visit
Who fixes it
You, then technician

This site is not affiliated with Daikin; this is an independent explanation.

This Daikin error code list explains the codes that show on the indoor display or blink on the lamp of a Daikin split, inverter or cassette AC. Each code is a letter plus a digit, such as L5, U0, E9 or C4. The letter points to an area of the AC and the digit points to the exact fault that the control board found.

Meanings can change between models and years, so treat this page as the common meaning on most models. Your remote, the sticker inside the front panel or the user manual has the final table. Anything that touches wiring, the circuit board, the outdoor unit or the gas is work for a trained Daikin technician, so the steps below only cover what is safe for you to do at home.

Common causes

  • 1Power supply problem or voltage swings

    How to tellCode appears after a power cut, a storm or when other heavy loads start

    What fixes itSwitch the AC off at its MCB for 5 minutes, then restart; fit a proper stabiliser if voltage is poor

  • 2Dirty filter or blocked indoor coil

    How to tellWeak cooling, ice on the pipe, or a code linked to airflow or freezing

    What fixes itClean the filters and let any ice melt fully before restarting

  • 3Sensor (thermistor) reading out of range

    How to tellCodes like C4, C9 or H9 with strange cooling or early cut off

    What fixes itNeeds a technician to test or replace the sensor

  • 4Indoor to outdoor communication fault

    How to tellU4 or UA, indoor lamp blinks, outdoor unit does not start

    What fixes itCheck the AC has power at both ends, then call service for the cable and boards

  • 5Blocked drain or float switch trip

    How to tellA3 with water dripping, a full drain pan or a cassette that stops

    What fixes itStop the AC, clear visible drain blockage; a technician checks the pump

  • 6Compressor or inverter protection

    How to tellL5, E5, E6 or E9 style codes after repeated start attempts

    What fixes itDo not keep restarting; book authorised service

  • 7Low refrigerant or a leak

    How to tellU0 with poor cooling, frost on the thin pipe or an oily joint

    What fixes itRefrigerant work is for a trained technician only

How to fix it, step by step

  1. Note the code and when it appears

    Write down the exact code and what the AC was doing: just switched on, running for an hour, or after rain. Check whether it is a lamp blinking or a code on a display. A clear note saves the technician time and helps you match the code below.

  2. Switch off at the MCB for five minutes

    Turn the AC off with the remote, then switch off its own breaker at the board. Wait five minutes so the control board resets, switch back on and start the AC again. Many one time codes after a power dip disappear with this alone.

  3. Clean the washable air filters

    Open the front panel, slide out the mesh filters and rinse them under a tap with plain water. Let them air dry out of the sun and refit. A choked filter leads to coil icing and several protection codes.

  4. Check the room, the remote and the mode

    Keep doors closed and make sure nothing blocks the air flow of the indoor unit. Replace the remote batteries and select Cool at a normal set temperature. A wrong mode can look like a fault.

  5. Look for water or ice, never open the casing

    If you see ice on the indoor unit or water at the outlet, turn the AC off and run only the fan mode for an hour to melt it. Do not remove the panels beyond the filter door and never open the outdoor unit.

  6. Restart once, then stop if the code returns

    Should it flash again soon after starting, leave the AC off. Repeated starts can stress the compressor and turn a small fault into a costly one.

  7. Book authorised Daikin service with your notes

    Share the model name from the indoor label, the code and the steps you tried. Ask the technician to confirm the code on your model and to explain the repair before work starts. See also our AC not working checklist.

Daikin error code list for split and inverter ACs

Common Daikin codes and what they usually point to
CodeUsual meaning on most modelsWho fixes it
00Normal, no fault storedNothing to fix
A1Indoor control board problemTechnician
A3Drain water level problemYou (clear drain), then technician
A5Freeze up or high pressure protectionYou (filters), then technician
A6Indoor fan motor stuck or overloadedTechnician
C4Indoor coil temperature sensor faultTechnician
C9Room temperature sensor faultTechnician
E1Outdoor board faultTechnician
E5Compressor motor locked or overloadedTechnician
E7Outdoor fan motor faultTechnician
E9Expansion valve faultTechnician
L5Inverter or compressor overcurrentTechnician
U0Refrigerant shortageTechnician
U2Supply voltage out of rangeYou (check power), then technician
U4 or UAIndoor and outdoor not communicatingTechnician

Some older or simpler models use fewer codes, and a few use the same code for two causes. That is why the label inside your unit matters more than any list on the web.

Reading L5, U0, U2 and E9 in plain words

L5 means the inverter board saw too much current when the compressor tried to run. It can follow a voltage dip, but it also points to a weak compressor or board, so a technician must test it.

U0 is the code people fear most because it points to low refrigerant. The gas does not get used up, so low gas means a leak, and finding it needs proper tools.

U9 is seen on multi room systems when another indoor unit has a fault, so look at the other rooms too. U2 says the supply voltage is too low, too high or unsteady. See whether fans and lights also sag or trip when the AC starts.

E9 is about the electronic expansion valve, the part that meters refrigerant. It is outdoor side work.

Your living room AC cools for ten minutes and then the lamp blinks twice with U4 on the remote screen. The indoor unit has power but cannot talk to the outdoor unit, so the compressor never starts. Check that the outdoor isolator is on, then call service.

Cassette, ceiling and inverter models behave a little differently

Cassette and ducted Daikin units (the daikin cassette ac a3 error code is a common search) often show A3 because they use a drain pump with a float switch. If the pump fails or the drain line slopes wrongly, water rises and the AC stops to protect the ceiling. Inverter splits add inverter board codes such as L5, while basic non inverter models may show only a few sensor and fan codes.

Do not assume a code from a friend's AC applies to yours. Compare the model number on the indoor label and ask the service centre to confirm.

What makes a Daikin repair cost more

Sensors and filters are the cheap end. Costs rise when the repair needs an outdoor board, a fan motor, a compressor, a leak search or refilling, or when the unit is high on a wall or on an upper floor and needs extra equipment to reach. Before you say yes, get the faulty part named and the price put on paper.

Opening the unit yourself or using an unqualified person can void the warranty and is unsafe. Gas and electrical work must be done by a trained technician.

How to avoid repeat codes

Clean the filters every two to four weeks in the cooling season, keep the outdoor unit clear of dust, cloth and water, and book a yearly service before summer. Use a fixed supply with a good breaker and not an extension board. For codes of other brands, the AC error codes overview shows how the families compare, and the single code page for Daikin F3 and Daikin U4 go deeper.

Frequently asked questions

What does the L5 error code mean on a Daikin AC?

On most models L5 means the inverter saw an overcurrent when starting the compressor. A voltage dip can trigger it once, but if it repeats the board or compressor needs a technician.

What is the U0 error code in Daikin?

U0 usually means refrigerant shortage. Because gas is sealed in the system, low gas points to a leak. Do not refill it yourself; ask authorised service to find the leak.

Daikin E9 error code: can I fix it myself?

No. E9 normally refers to the expansion valve in the outdoor side, so only a technician should check it. You can only reset power and confirm the AC has steady supply.

What does U2 mean on a Daikin?

U2 means the supply voltage is out of range. Check for power fluctuation, loose supply wiring or a weak stabiliser, and ask an electrician to look if the room lights sag each time the compressor starts.

What does the 00 code mean on Daikin?

On most models 00 means the error history is clear or no fault is stored. If the AC is working badly with 00 shown, the cause is probably airflow, gas or a sensor reading, so check service history.

Where can I get a Daikin error code list pdf?

The user manual or the service page for your exact model has the official table. Find the model name on the indoor label and request the matching code sheet from the authorised centre.